New Nickel & Zinc Targets for 100% Owned PL 59
Released
Released
Announcement PDF
ABN 96 122 995 073
ASX Code: BML
TO:
COMPANY ANNOUNCEMENTS OFFICE
ASX LIMITED
DATE:
5 OCTOBER 2015
“THIS IS A PRIORITY ITEM”
NEW NICKEL & ZINC TARGETS FOR 100% OWNED PL 59
SUMMARY OF FINDINGS: FOR PL 59/2008 - 100% OWNED BY BML
ZINC AT PL 59:
NEW ZINC ANOMALIES CONFIRMED
Highly elevated Zinc geochemical anomalies identified on PL 59 at Mashambe
project.
SQUID TECHNOLOGY FINDS NUMEROUS NICKEL DRILL TARGETS FOR PL 59:
Squid EM surveys identify numerous strong conductors along strike of Maibele
North (at least 6 EM conductors).
The EM anomalies are only 4km east of the Maibele North JORC Ni +Cu+ PGE’s
resource (JV between BML & BCL Limited).
Drilling is planned in October 2015 on 100% owned PL.
Media Statement: BML’s Chairman Mr Pat Volpe said “All Squid EM anomalies recently
drilled around Maibele North by the JV have intersected Ni & Cu sulphide
mineralisation.”
“If planned drilling at PL 59 hits sulphide mineralisation, this will open up the potential
for a substantial increase to the known mineralisation and confirm the size of a
significant strike length extending to the east of the Maibele North JV ground into the
100% owned BML licence PL 59.”
“A new and additional project focus will be born for our company.” Mr Volpe said.
The Board of Botswana Metals Limited is extremely excited by the positive SQUID
results on its 100% owned PL 59/2008 (PL 59). These strong results are reminiscent of
the features indicative of Ni-sulphide mineralisation at Maibele North and should drilling
of the new targets be successful it will signify a new discovery zone and open up the
potential for further discovery on BML’s 100% owned ground.
Botswana Metals Limited
REGISTERED OFFICE
Suite 506, Level 5, 1 Princess Street Kew Vic Australia 3101
P: +61 3 9855 1885; F: +61 3 9855 2885
Email info@botswanametals.com.au
www.botswanametals.com.au
ABN 96 122 995 073
Several elevated Zinc geochemical anomalies were also identified.
Details:
Botswana Metals Limited is pleased to advise that results and interpretations from the SQUID
EM surveys recently undertaken on BML’s 100% owned prospecting licence PL 59/2008 (PL
59) during have been received.
The SQUID TDEM program was undertaken over 3 prospects on PL 59 that are interpreted to
lie directly along strike from Maibele North where the SQUID has been used to great effect in
discovering additional mineralisation. The surveys detected significant conductors at all three
prospects and will be followed up by a drilling program designed to test the highest priority
targets.
Survey Highlights:
A total of 6 significant isolated conductors detected across the 3 prospects.
Depth to top of conductors range from 155m to 240m.
Cumulative strike length of the 6 conductors is over 2km.
All conductors are in favourable structural settings associated with ultramafic
intrusions and anomalous geochemistry.
To date every SQUID anomaly drilled at Maibele North has intersected Sulphides.
A focused drill program targeting the highest priority conductors is planned.
Figure 1: VTEM image showing the position of the PL 59 prospects along strike from
Maibele North.
Botswana Metals Limited
REGISTERED OFFICE
Suite 506, Level 5, 1 Princess Street Kew Vic Australia 3101
P: +61 3 9855 1885; F: +61 3 9855 2885
Email info@botswanametals.com.au
www.botswanametals.com.au
ABN 96 122 995 073
Program Details:
PL 59/2008 is a particularly attractive exploration target because it contains a number of
prospects that lie along strike from Maibele North on a geological horizon that is interpreted to
be a preferential host to Ni - Cu mineralisation in the district.
The PL contains three priority prospects, Maibele North Extension, Mashambe and Mashambe
NE that all show good indicators of potential Ni + Cu mineralisation similar to that displayed at
Maibele North and have been discovered through soil geochemical surveys, geological
mapping and airborne VTEM surveys.
The prospects lie along an interpreted geological horizon that contains a number of Ni + Cu
occurrences including the Maibele North Resource, with Maibele Extension some 4 km east of
Maibele North and Mashambe a further 6km east of Maibele North Extension.
Figure 2: Shows the potential strike length and its direction through BMLs 100% owned
PL 59/2008. The three VTEM anomalies show up in red at Maibele North Extension and
Mashambe.
Spectral Geophysics from Gaborone, Botswana, was commissioned to undertake the program
that included a total of six separate loops across the 3 prospects: 4 at Maibele North Extension
and 1 each at Mashambe and Mashambe NE. Spectral Geophysics were the contractors who
successfully identified new conductors currently being drilled at nearby Maibele North.
The details of the survey and loops are:
• SENSOR – Jena Jesse Deep 3 component SQUID.
• RECEIVER – Emit SMARTEM24 16 Channel.
• TRANSMITTER – Monex Geoscope tx50.
Botswana Metals Limited
REGISTERED OFFICE
Suite 506, Level 5, 1 Princess Street Kew Vic Australia 3101
P: +61 3 9855 1885; F: +61 3 9855 2885
Email info@botswanametals.com.au
www.botswanametals.com.au
ABN 96 122 995 073
•
•
•
•
•
TRANSMITTER LOOP SIZE – 800m X 500m.
LINE SPACING – 150m.
LINE LENGTH – 1000m.
STATION SPACING – 50m with 25m infill.
TRANSMITTER BASE FREQUENCY – 1 Hz.
Results
Maibele North Extension – Four Loops (E1, E2, E3, E4)
3 isolated, discreet conductors defined from loops E1,E2,E4.
Cumulative total strike length of conductors ~ 900m.
Conductance increases from west to east.
Average depth to top of conductors in the range 110 -165m.
Average dip of conductors in the range 57° - 75°.
Conductance of plates for E1, E2 in the range 100s – 500s.
Conductance of plates for E4 >1500s.
Additional Prospect Information
~4km from Maibele North.
Ultramafic Rocktypes present.
Two modelled VTEM Conductors – 11420a, 11470a.
Favourable Cu and Ni soil geochemical anomalies.
Mashambe – One Loop (E1)
2 isolated, discreet conductors defined from loop E1 (one of which could be related to
casing stuck in old drill hole).
Total strike length of conductors ~ 700m.
Average depth to top of conductors in the range 220 -240m.
Average dip of conductors in the range 66° - 71°.
Average conductance of plates in the range 280s – 310s.
Additional Prospect Information
10km from Maibele North, 6km from Maibele North Extension.
Ultramafic Rocktypes present.
Associated modelled VTEM Conductor – 11870b.
Favourable Cu and Ni soil geochemical anomalies.
Botswana Metals Limited
REGISTERED OFFICE
Suite 506, Level 5, 1 Princess Street Kew Vic Australia 3101
P: +61 3 9855 1885; F: +61 3 9855 2885
Email info@botswanametals.com.au
www.botswanametals.com.au
ABN 96 122 995 073
Mashambe North East – One Loop (E1)
1 isolated, discreet conductor defined from loop E1.
Total strike length of conductor ~ 440m.
Average depth to top of conductor in the range 155 -170m.
Average dip of conductors in the range 70° - 80°.
Average conductance of plates in the range 300s – 460s.
Good conductor with favourable structural setting.
Conductor located just within the JV tenement PL 54/98.
Additional Prospect Information
15km from Maibele North, 4km from Mashambe.
Ultramafic Rocktypes present.
Associated modelled VTEM Conductor 12100a.
Favourable Cu and Ni soil geochemical anomalies.
Mashambe: Zinc geochemical anomalies:
It should also be noted that highly elevated Zinc soil geochemical anomalies exist at
Mashambe and rock chips of up to 0.79g/t Au have been collected at Mashambe Northeast.
These, along with any other features of interest will be followed up in the course of the
exploration program.
Figure 3: Location of the PL 59 SQUID conductors (pink rectangles) at the 3 prospects
over the regional VTEM image.
Botswana Metals Limited
REGISTERED OFFICE
Suite 506, Level 5, 1 Princess Street Kew Vic Australia 3101
P: +61 3 9855 1885; F: +61 3 9855 2885
Email info@botswanametals.com.au
www.botswanametals.com.au
ABN 96 122 995 073
Proposed Drill Program
An initial program of 3 drill holes for 775m is proposed to test the conductors at Maibele North
Extension. These conductors rank as the highest priority targets due to:
Close proximity along strike to Maibele North.
Multiple conductors of increasing conductivity (to over 1500s).
Shallow depth (~165m).
Multiple targets of a cumulative strike to 900m – possibly indicates a large system with
potential for numerous orebodies.
The drill program is expected commence in October 2015 and the market will be informed
when drilling commences.
SQUID EM TECHNOLOGY:
A SQUID (superconducting quantum interference device) is a very sensitive magnetometer
used to measure extremely subtle magnetic fields, based on superconducting loops containing
Josephson junctions. The SQUID technology has many uses and is often employed in the
medical industry in such application as Magnetic Resonance Imaging (MRI). In minerals
exploration, the SQUID EM technique can be used to accurately detect very deep conductors
potentially associated with sulphide accumulations.
Patrick Volpe
Chairman
The information in this report that relates to Exploration Results is based on, and fairly represents, information and
supporting documentation compiled by BML staff on site and provided to Mr Steve Groves who is a Member of
The Australasian Institute of Mining and Metallurgy. Mr Groves is a consulting geologist to BML and has previously
been employed as the Exploration Manager at BML. Mr Groves has sufficient experience which is relevant to the
style of mineralisation and type of deposit under consideration and to the activity which he is undertaking to qualify
as a Competent Person as defined in the 2012 Edition of the ‘Australasian Code for Reporting of Exploration
Results, Mineral Resources and Ore Reserves’. Mr Groves consents to the inclusion in this report of the matters
based on his information in the form and context in which it appears.
Botswana Metals Limited
REGISTERED OFFICE
Suite 506, Level 5, 1 Princess Street Kew Vic Australia 3101
P: +61 3 9855 1885; F: +61 3 9855 2885
Email info@botswanametals.com.au
www.botswanametals.com.au
ABN 96 122 995 073
APPENDIX 1 – JORC Code, 2012 Edition – Table 1
Section 1 Sampling Techniques and Data
(Criteria in this section apply to all succeeding sections)
CRITERIA
Sampling
techniques
JORC Code Explanation
Commentary
- Nature and quality of sampling (eg cut
channels, random chips, or specific
specialised industry standard measurement
tools appropriate to the minerals under
investigation, such as down hole gamma
sondes, or handheld XRF instruments, etc.).
These examples should not be taken as
limiting the broad meaning of sampling.
- Include reference to measures taken to ensure
sample representivity and the appropriate
calibration of any measurement tools or
systems used.
- Aspects of the determination of mineralisation
that are Material to the Public Report.
- In cases where ‘industry standard’ work has
been done this would be relatively simple (eg
‘reverse circulation drilling was used to obtain
1 m samples from which 3 kg was pulverised
to produce a 30 g charge for fire assay’). In
other cases more explanation may be
required, such as where there is coarse gold
that has inherent sampling problems. Unusual
commodities or mineralisation types (eg
submarine nodules) may warrant disclosure of
detailed information.
Sample geochemical data referenced
in this release are from surface soil
sampling programs.
Where referenced, soil samples are
taken at regular spacing from an
appropriate grid across a
prospective area
The top 5cm of material above and
below the site must be removed to
avoid contamination issues. Samples
to be taken from the B horizon at
depths of approximately 30 - 45cm.
Soil is then taken from the bottom of
the pit and a 2Kg bulk sample
(approx.) will be taken at each site.
Sample preparation will vary from
project to project. Samples may be
sieved to separate the coarse and
fine fractions for analysis
The parameters describing this
sample location are collected on the
soil sample sheet and these must be
completed as fully as possible
The Sample_ID should be confirmed
with the sample location. The
Sample_ID must be written on the
outside of the kraft geochem packet.
A sample ticket must be dropped
into the geochem envelope.
The sample ticket tag must be
completed with the Data and Time of
Sampling and the person who
sampled. It must be completed in
PEN, not in pencil.
Do not wear jewellery.
All soil samples referenced in this
release were assayed at an
independent laboratory (ALS, South
Africa) via the AQUA-REGIA ACID
DIGESTION AND ICP-AES method
before interpretation
No new drilling has been referenced
in this release. Any reference to drill
holes relates to historic holes.
Botswana Metals Limited
REGISTERED OFFICE
Suite 506, Level 5, 1 Princess Street Kew Vic Australia 3101
P: +61 3 9855 1885; F: +61 3 9855 2885
Email info@botswanametals.com.au
www.botswanametals.com.au
ABN 96 122 995 073
CRITERIA
Drilling
techniques
Drill sample
recovery
JORC Code Explanation
Commentary
Drill type (eg core, reverse circulation ,openhole hammer, rotary air blast, auger,
Bangka, sonic, etc.) and details (eg core
diameter, triple or standard tube, depth of
diamond tails, face sampling bit or other
type, whether core is oriented and if so, by
what method, etc.).
No new drilling has been referenced
in this release. Any reference to drill
holes relates to historic holes.
Historic holes have been either NQ
core, HQ core or Reverse Circulation
percussion methods
Method of recording and assessing
core and chip sample recoveries and
results assessed.
Measures taken to maximise sample
recovery and ensure representative
nature of the samples.
Whether a relationship exists between
sample recovery and grade and
whether sample bias may have
occurred due to preferential loss/gain
of fine/coarse material.
No new drilling has been referenced
in this release. Any reference to drill
holes relates to historic holes.
Whether core and chip samples have been
geologically and geotechnically logged to a
level of detail to support appropriate
Mineral Resource estimation, mining
studies and metallurgical studies.
Whether logging is qualitative or
quantitative in nature. Core (or
costean, channel, etc.) photography.
The total length and percentage of
the relevant intersections logged.
No new drilling has been referenced
in this release. Any reference to drill
holes relates to historic holes.
If core, whether cut or sawn and
whether quarter, half or all core taken.
If non-core, whether riffled, tube sampled,
rotary split, etc. and whether sampled wet
or dry.
For all sample types, the nature, quality
and appropriateness of the sample
preparation technique.
Quality control procedures adopted for
all sub-sampling stages to maximise
representivity of samples.
Measures taken to ensure that the
sampling is representative of the in situ
material collected, including for instance
results for field duplicate/second-half
sampling.
Whether sample sizes are appropriate
to the grain size of the material being
sampled.
No new drilling has been referenced
in this release. Any reference to drill
holes relates to historic holes.
For soil sampling:
The insertion of QA/QC samples is
undertaken. Blanks, standards or
field duplicates are added
approximately every twenty samples.
Good blank material is pool filter
sand. Low grade standards are
recommended over high grade as the
assay values are likely to be at lower
levels.
Field duplicates must be a portion of
a larger sample collected in the field
so as to reflect a good reproducibility
(i.e. collect sample, sieve and split
into two samples, one original and
one duplicate).
Logging
Subsampling
techniques
and sample
preparation
Botswana Metals Limited
REGISTERED OFFICE
Suite 506, Level 5, 1 Princess Street Kew Vic Australia 3101
P: +61 3 9855 1885; F: +61 3 9855 2885
Email info@botswanametals.com.au
www.botswanametals.com.au
ABN 96 122 995 073
CRITERIA
Quality of
assay data
and
laboratory
tests
JORC Code Explanation
Commentary
Any new soil results discussed in this
release have been analysed in the
field using a handheld XRF machine.
The details of the instruments used
include:
Olympus Innov-X Delta Premium
portable XRF analyzer is used with a
Rhenium anode in soil and mines
mode at a tube voltage of 40kV and a
tube power of 200µA. The resolution
is around 156eV @ 40000cps. The
detector area is 30mm2 SDD2. A
power source of Lithium ion batteries
is used. The element range is from P
(Z15 to U (Z92). A cycle time of 120
seconds Soil Mode was used and
beam times were 40 seconds. A
propylene3 window was used. No
calibration factors were applied.
Blanks and standards are analysed at
after every 5th XRF sample.
Surface XRF analysis of this type is
used
to
determine
element
anomalism relative to a regional
background.
Concentrations
are
c o n s i d e r e d approximate only and
anomalism
is
determined
as
statistically relative to the determined
regional background levels.
The data were examined by the senior
personnel on site.
The primary data were audited and
verified and then stored in a SQL
relational database.
No data have been adjusted..
Verification
of sampling
and
assaying
Location
of data
points
Data spacing
and
distribution
The nature, quality and appropriateness
of the assaying and laboratory
procedures used and whether the
technique is considered partial or total.
For geophysical tools, spectrometers,
handheld XRF instruments, etc, the
parameters used in determining the
analysis including instrument make and
model, reading times, calibrations
factors applied and their derivation, etc.
Nature of quality control procedures
adopted (e.g. standards, blanks,
duplicates, external laboratory checks)
and whether acceptable levels of
accuracy (i.e. lack of bias) and precision
have been established.
The verification of significant
intersections by either independent or
alternative company personnel.
The use of twinned holes.
Documentation of primary data, data
entry procedures, data verification, data
storage
(physical and electronic)
protocols.
Discuss any adjustment to assay data.
Accuracy and quality of surveys used to
locate drill holes (collar and down-hole
surveys), trenches, mine workings and
other locations used in Mineral
Resource estimation.
Specification of the grid system used.
Quality and adequacy of
topographic control.
Data spacing for reporting of
Exploration Results.
Whether the data spacing and distribution
is sufficient to establish the degree of
geological and grade continuity appropriate
for the Mineral Resource and Ore Reserve
estimation procedure(s) and classifications
applied.
Whether sample compositing has
been applied.
Botswana Metals Limited
The data were recorded in
longitude/latitude WGS84.
The terrain is largely flat.
Soil sampling points and geophysical
survey lines are located on the
ground using a handheld GPS with an
accuracy of <5m
All historic drillholes have been
surveyed using DGPS with an
accuracy of <1m.
Soil Samples are typically taken from
a grid established over the
prospective area.
Sample lines are spaced is at an
interval deemed appropriate to cover
the features of interest (e.g. 200m or
100m)
Sample spacing along lines is at an
interval deemed appropriate to cover
the features of interest (e.g. 50m
REGISTERED OFFICE
Suite 506, Level 5, 1 Princess Street Kew Vic Australia 3101
P: +61 3 9855 1885; F: +61 3 9855 2885
Email info@botswanametals.com.au
www.botswanametals.com.au
ABN 96 122 995 073
CRITERIA
JORC Code Explanation
Orientation
of data in
relation to
geological
structure
Sample
security
Audits or
reviews
Commentary
spacing)
Areas of anomalous response are
often followed up with infill soil
sampling lines between the original
lines (e.g.100m or 50m spacing)
Soil sample lines are generally
orientated perpendicular to the
geological or interpreted structural or
mineral trends of interest
Sample spacing along lines is at an
interval deemed appropriate to cover
the features of interest (e.g. 25m, 50m
or 100m spacing)
Whether the orientation of sampling
achieves unbiased sampling of
possible structures and the extent to
which this is known, considering the
deposit type.
If the relationship between the drilling
orientation and the orientation of key
mineralised structures is considered to
have introduced a sampling bias, this
should be assessed and reported if
material.
The measures taken to ensure sample
security.
Samples were taken and transported
by BML personnel to the BML site
office Prior to analyses the samples
are locked in the BML office
The data were examined by the
independent consultant Mr. Steve
Groves of Perth in Australia and
considered appropriate
The results of any audits or reviews of
sampling techniques and data.
Section 2 Reporting of Exploration Results
(Criteria in this section apply to all succeeding sections)
CRITERIA
Mineral
tenement and
land tenure
status
Exploration
done by other
parties
JORC Code Explanation
Commentary
- Type, reference name/number, location and
ownership including agreements or material
issues with third parties such as joint
ventures, partnerships, overriding royalties,
native title interests, historical sites,
wilderness or national park and
environmental settings.
- The security of the tenure held at the time
of reporting along with any known
impediments to obtaining a licence to
operate in the area.
The results reported in this
Announcement are located in PL
59/2008 which is a granted
Exploration Licence held by African
Metals (Pty) Ltd, a 100% owned
subsidiary of Botswana Metals
Limited.
PL 59/2008 is 100% owned by African
Metals (Pty) Ltd and is not subject to
the Joint Venture agreement with BCL
Limited.
PL 59/2008 expires on 30 September
2016 and is currently in good
standing.
- Acknowledgment and appraisal of
exploration by other parties.
All interpretations and conclusions in
this announcement are based on
results generated by historic
exploration work conducted by Cardia
Mining and Botswana Metals.
Botswana Metals considers all
previous exploration work to have
been undertaken to an appropriate
professional standard.
Botswana Metals Limited
REGISTERED OFFICE
Suite 506, Level 5, 1 Princess Street Kew Vic Australia 3101
P: +61 3 9855 1885; F: +61 3 9855 2885
Email info@botswanametals.com.au
www.botswanametals.com.au
ABN 96 122 995 073
CRITERIA
JORC Code Explanation
Commentary
- Deposit type, geological setting and style of
mineralisation.
The Prospecting Licence PL 59/2008
is hosted within the Magogaphate
Shear Zone - a major geological
structural
feature,
generally
considered to mark the boundary
between the Archaean aged (>2.5
billion year old) Zimbabwean Craton
and the Limpopo Belt or Limpopo
Mobile Zone (LMZ). . The nickelcopper deposits of Selebi Phikwe lie
within the northern part of the
Central Zone of the Limpopo Mobile
Belt, whilst the nickel copper
deposits of Phoenix, Selkirk and
Tekwane lie in the Zimbabwean
Craton. The Central Zone of the LMZ
comprises variably deformed banded
gneisses and granitic gneisses,
infolded amphibolites and ultramafic
intrusions that that have the
potential to host Ni-Cu sulphide
mineralization.
Ni-Cu-PGE
mineralization at Maibele North and
Airstrip
copper
is
spatially
associated
with
an
ultramafic
intrusion.
Drill hole
Information
- A summary of all information material to the
understanding of the exploration results
including a tabulation of the following
information for all Material drill holes:
o easting and northing of the drill hole
collar
o elevation or RL (Reduced Level –
elevation above sea level in metres) of
the drill hole collar
o dip and azimuth of the hole
o down hole length and interception depth
o hole length.
- If the exclusion of this information is justified
on the basis that the information is not
Material and this exclusion does not detract
from the understanding of the report, the
Competent Person should clearly explain
why this is the case.
N/A
Data
aggregation
methods
- In reporting Exploration Results, weighting
averaging techniques, maximum and/or
minimum grade truncations (eg cutting of
high grades) and cut-off grades are usually
Material and should be stated.
- Where aggregate intercepts incorporate
short lengths of high grade results and
longer lengths of low grade results, the
procedure used for such aggregation
should be stated and some typical
examples of such aggregations should be
shown in detail.
- The assumptions used for any reporting of
N/A
Geology
Botswana Metals Limited
REGISTERED OFFICE
Suite 506, Level 5, 1 Princess Street Kew Vic Australia 3101
P: +61 3 9855 1885; F: +61 3 9855 2885
Email info@botswanametals.com.au
www.botswanametals.com.au
ABN 96 122 995 073
CRITERIA
JORC Code Explanation
Commentary
metal equivalent values should be clearly
stated.
Relationship
between
mineralisation
widths and
intercept
lengths
- These relationships are particularly
important in the reporting of Exploration
Results.
- If the geometry of the mineralisation with
respect to the drill hole angle is known, its
nature should be reported.
- If it is not known and only the down hole
lengths are reported, there should be a clear
statement to this effect (eg ‘down hole
length, true width not known’).
N/A
Diagrams
- Appropriate maps and sections (with
scales) and tabulations of intercepts should be
included for any significant discovery being
reported These should include, but not be
limited to a plan view of drill hole collar
locations and appropriate sectional views.
Plan view and/or cross section maps
of the reported exploration results are
included in this announcement.
Balanced
reporting
- Where comprehensive reporting of all
Exploration Results is not practicable,
representative reporting of both low and
high grades and/or widths should be
practiced to avoid misleading reporting of
Exploration Results.
No grades or drill intercepts are
referred to in this announcement.
Reference is made to interpreted
geophysical and/or geochemical
anomalies that have been delineated
by relative comparisons to
background responses.
Other
substantive
exploration
data
- Other exploration data, if meaningful and
material, should be reported including (but not
limited to): geological observations;
geophysical survey results; geochemical
survey results; bulk samples – size and
method of treatment; metallurgical test
results; bulk density, groundwater,
geotechnical and rock characteristics;
potential deleterious or contaminating
substances.
Interpretations in this release have
incorporated
data,
images
and
models from airborne and ground
geophysical surveying.
In 2011, a comprehensive helicopterborne VTEM (Versatile Time Domain
Electromagnetic)
Survey
was
undertaken across BML’s tenements
in Botswana
The survey included the collection of
EM, magnetic and terrain data.
Flight height - 75m
Line Spacing – 150m
Data
processing
and
model
construction was undertaken offsite
by consultant geophysicists
In 2015, ground geophysical surveys
were undertaken using the SQUID EM
technology. These were fixed loop
surveys
recommended
by
the
consultant
geophysicist.
All
processing and modelling of data was
Botswana Metals Limited
REGISTERED OFFICE
Suite 506, Level 5, 1 Princess Street Kew Vic Australia 3101
P: +61 3 9855 1885; F: +61 3 9855 2885
Email info@botswanametals.com.au
www.botswanametals.com.au
ABN 96 122 995 073
CRITERIA
Further work
JORC Code Explanation
Commentary
- The nature and scale of planned further
work (eg tests for lateral extensions or
depth extensions or large-scale step-out
drilling).
- Diagrams clearly highlighting the areas of
possible extensions, including the main
geological interpretations and future drilling
areas, provided this information is not
commercially sensitive.
completed off site by Cas Lotter of
Spectral
Geophysics,
Gaborone,
Botswana.
The details of the survey and loops
referred to in this document are:
o
SENSOR – Jena Jesse Deep 3
component SQUID
o
RECEIVER – Emit SMARTEM24
16 Channel
o
TRANSMITTER – Monex
Geoscope tx50
o
TRANSMITTER LOOP SIZE –
800m X 500m
o
LINE SPACING – 150m
o
LINE LENGTH – 1000m
o
STATION SPACING – 50m with
25m infill
o
TRANSMITTER BASE
FREQUENCY – 1 Hz
This announcement describes the
immediate work program for
BML’s regional exploration areas.
Early stage work such as
geological mapping, soil sampling
and ground geophysics will be
undertaken with a view to
generating drill targets in
prospective areas
Botswana Metals Limited
REGISTERED OFFICE
Suite 506, Level 5, 1 Princess Street Kew Vic Australia 3101
P: +61 3 9855 1885; F: +61 3 9855 2885
Email info@botswanametals.com.au
www.botswanametals.com.au
Share your feedback
Discover